99999色_亚洲日韩亚洲另类激情文学_久久精品亚洲成在人线av麻豆_欧美色香蕉_女人下边被添全过程A片图片_在线观看黄的网站

Plasma cleaning for UHV applications: particle accelerators
Release time : 2025-04-23
View volume : 640

Scan the code to browse this page on your phone

Plasma cleaning for UHV applications: particle accelerators  

Hyper-clean Surfaces

 

UHV critical components, such as those used extensively in surface science laboratories and particle accelerators, are required to meet strict cleanliness criteria of which pre-installation cleaning is an important step. Daresbury Laboratory based in the UK and a centre for worldwide particle accelerator technology, approached Henniker Plasma to look at the potential of oxygen plasma cleaning as part of the stringent pre-cleaning process.

Plasma cleaning was assessed by measurement of electron stimulated desorption yields. Together, we were then able to compare the results from using traditional solvent-based cleaning together with plasma cleaning.

 

Solvent Cleaning Technique 

A hydrofluoroether (HFE) type solvent was employed at Daresbury Laboratory as the primary cleaning solvent of choice, having been chosen from the outcome of earlier studies of the effects of various cleaning techniques on outgassing and electron stimulated desorption from stainless steel [1].

 

The steps used in the HFE procedure are as follows;

  1.  
  2. 1. Manual detergent wash
  3. 2. Rinse in de-mineralised water
  4. 3. 15 minutes of aqueous wash using a standard detergent
  5. 4. Rinse in de-mineralised water
  6. 5. 15-minute ultrasonic clean in HFE
  7. 6. 15-minute vapour clean in HFE
  8. 7. Rinse in de-mineralised water
  9. 8. Dry in the oven (80°C)

 

Plasma Cleaning

When gas atoms are ionised, the collision of high energy particles knocks electrons out of their orbits. This results in the characteristic “glow” or light associated with plasma. Plasmas contain many different species including atoms, molecules, ions, electrons, free radicals, metastables, and photons in the short wave ultraviolet (vacuum UV or VUV) range. Plasmas are generated in closed vessels at low pressures, typically < 1.0 Torr. The low pressure results in a long mean free path of the plasma species so that they remain reactive until contact with a surface. The overall chamber temperature at the commonly used power levels and pressures is close to room temperature.

The gas used in these experiments was oxygen. The VUV energy is effective in breaking the organic bonds (i.e., C-H, C-C, C=C, C-O, and C-N) of surface contaminants. This helps to break apart high molecular weight contaminants. A second cleaning action is carried out by the oxygen species created in the plasma (O2+, O2-, O3, O, O+, O-, ionised ozone, metastably-excited oxygen, and free electrons). These species react with organic contaminants to form H2O, CO, CO2, and lower molecular weight hydrocarbons. These compounds have relatively high vapour pressures and are easily evacuated from the chamber.

 

Measurement of Sample Cleanliness

Stainless steel samples were first contaminated with a variety of contaminants including oils, grease, fingerprints and marker pen. Sample cleanliness was then assessed by measuring the electron stimulated desorption yield, calculated by the throughput at the conductance:-  

Where Nm= number of desorbed molecules, Ne= number of incident electrons, qe= electron charge, kB= Boltzmann’s constant, T= chamber temperature, Iesd= drain current, Q= throughput.

 

Figure 1. ESD Experimental Arrangement

  •  
  • - Other essential features of the experiment were:
  • - Cylinder biased to +200V
  • - Coaxial electron source
  • - Variable conductance: 143 ltr.sec-1 (mass 28) for ESD
  • - Calibrated pressure measurement
  • - Sample drain current measured during ESD

Results and Discussion  

The results shown in Chart 1 demonstrate that there is a clear improvement in electron stimulated desorption yield (sample cleanliness) when plasma cleaning is used in addition to the solvent cleaning procedure described.

The measured electron stimulated desorption yield with the additional plasma cleaning step is almost the same as the yield from the uncontaminated samples. For this specific work, this result suggests that plasma cleaning could add benefits to vacuum components used in an accelerator environment due to the reduction in desorption yield and hence a smaller gas load to contend with.

The results of samples subjected to a reduced cleaning cycle in conjunction with plasma cleaning (ultrasonic HFE + plasma) are also better than the results obtained from the samples that had undergone the full HFE cleaning process. This suggests that the full HFE cleaning process could be reduced to just two stages, ultrasonic and plasma, and still produce samples of higher cleanliness.

Chart 1. Comparison of Cleaning Methods via Electron Stimulated Desorption Yield (molecules/electron)

 

The remaining samples (aqueous or vapour clean + plasma) all show similar results in that they are insufficient combinations of cleaning steps to produce UHV clean samples.

Our Solution

Using our bench-top plasma cleaner in combination with the traditional solvent-based cleaning routine described here produced cleaner surfaces, similar to those of uncontaminated surfaces, than solvent-based cleaning alone.

This example demonstrates that Plasma cleaning can

  1.  
  2. i) Reduce lengthy cleaning processes
  3. ii) Reduce the use of environmentally unfriendly solvents
  4. iii) Reduce the costs associated with handling, use and disposal of solvent-based cleaners.

 

The Daresbury Laboratories team worked closely with Henniker Plasma to ensure a solution which enhanced and determined their own objective in becoming a worldwide leader in particle accelerator technology. 

"Using our bench-top plasma cleaner in combination with the traditional solvent-based cleaning routine described here produced cleaner surfaces, than solvent-based cleaning alone."

——K.J.Middleman Daresbury.

 

Reference[1] K.J. Middleman, Vacuum 81 (2007) P793-798.

Source of the original text:

https://plasmatreatment.co.uk/knowledge-base/case-studies/132-plasma-cleaning-for-uhv-applications-particle-accelerators

上一篇:沒有了

LIST

下一篇:Researchers in China produce Ultra stable Semiconductor using Henniker HPT-100

Contact Us
Hong Kong 

Phone:+ 852 2755 6578

Address:Room 68,1/F, Sino Industrial Plaza, 9 Kai Cheung Road,
Kowloon Bay, Kowloon, Hong Kong

Shanghai 

Phone:400 886 0017

Address:8 / F, No. 3, Magnolia Environmental Plaza, Lane 251,
Songhuajiang Road, Yangpu District, Shanghai

? 2011-Now A&P Instrument Co., Ltd. All rights reserved

滬ICP備06031990號-1

滬公網安備31011002002121號

主站蜘蛛池模板: 精品久久久中文字幕人妻 | 在线成人精品国产区免费 | 日韩精品一区二区三区色 | 久久性生活免费视频 | 一本一道久久a久久精品 | 色图久久 | 秋霞影院亚洲国产中文精品 | 精品无人区无码乱码大片国产 | 亚洲天堂免费视频 | 国产成人8x人网站视频 | 操女人视频网站 | 一本大道亚洲视频 | 精品97国产免费人成视频 | 国产精品嫩草99a | 成人天堂视频第一网站 | 成人性生交大片免费看中文 | 天天噜噜噜在线视频 | 国产AⅤ爽AV久久久久玉浦团 | 中文字幕成人动漫 | av在线网站观看 | 亚洲第一大网站 | 亚洲AV成人无遮挡网站在线观看 | 国产尤物av尤物在线观看 | 超碰色偷偷 | 懂色av一区二区三区观看 | 黑人巨大人精品欧美三区 | 91av视频在线免费观看 | 97色精品视频在线观看 | 精品国产一区二区三区久久久樱花 | 男人插女人逼逼视频 | 肉蒲团从国内封禁到日本成经典 | 国产精品99久久久久的智能播放 | 久久大学生精品视频 | 亚洲欧美成人无码久久久 | 中文字幕永久视频在线看 | 91美剧网在线播放 | 91精品久久久高潮叫床九色91 | 最近2018中文字幕免费看2019 | 国产精品日本一区二区在线播放 | 97视频自拍 | 在线观看黄动漫 |